<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-25 07-25-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 14 kHz 16648 6,3671
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,7 dBr 2,96 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 14 kHz MIN: 9 kHz % above 76 kHz: 6,3671 Acquired: 2025/02/25 7.24.09 Total samples: 16648 Equivalent time: 0:13:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,6 dBr MIN: 0,7 dBr AVE: 2,96 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2025/02/25 7.24.09) 07.10 07.12 07.14 07.16 07.18 07.20 07.22 07.24 0 2 4 6 Pm [dBr]